THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER - PDF

Please download to get full document.

View again

of 8
All materials on our website are shared by users. If you have any questions about copyright issues, please report us to resolve them. We are always happy to assist you.
Information Report
Category:

Science & Technology

Published:

Views: 15 | Pages: 8

Extension: PDF | Download: 0

Share
Related documents
Description
Your Complete Turnkey Server Room Air Condition UPS THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER AVAILABLE IN WATER AND GAS SYSTEM MODEL AIR-CONDITIONED CABINET EXCELLENT TEMPERATURE CONTROL FOR
Transcript
Your Complete Turnkey Server Room Air Condition UPS THE OPTIMAL SOLUTION FOR SMALL AND MEDIUM DATA CENTER AVAILABLE IN WATER AND GAS SYSTEM MODEL AIR-CONDITIONED CABINET EXCELLENT TEMPERATURE CONTROL FOR VERY CRITICAL LOADS, INDEPENDENT FROM ENVIROMENTAL CONDITIONS OPTIMIZED SPACE DON T NEED A SPECIALROOM VERY EASY INSTALLATION LOW POWER CONSUMPTION PERFECT ELECTRICAL POWER SUPPLY, STABLE, REDUNDANT, WITH CONTINUITY OF POWER SUPPLY, NOISE-FREE READY FOR FUTURE EXPANSION OF THE COMPUTER SYSTEM Air Condition UPS Your Complete Turnkey Server Room The modern Data Center needs considerable electrical power, even used to cool the system. The infrastructures have become more and more important and expensive: consider for example the concentration of heat produced by modern blade servers and the dissipation within a limited temperature window, or shortage of open spaces. It s an obligation to optimize space and power consumption. Air Condition UPS is our solution for a small and medium-size Data Center. Air Condition UPS range includes several solutions for the different Data Centers power requirements. From the small Air Condition UPS in a sole cabinet, that is like a small data center room, to the modular Air Condition UPS that is designed to satisfy the most powerfull computers. Air Condition UPS is an air-conditioned cabinet: inside is located the server (and its accessories as hubs, switch boards, etc...), and the redundant modular uninterruptible power systems (UPS) with their sealed batteries. The air conditioner automatically optimizes both the temperature inside the cabinet and the energy consumption. Air Condition UPS Available space for server Electrical distribution Modular UPS Sealed Batteries Air Condition UPS MODULAR SYSTEM SERVER UPS + BATTE RY SERVER UPS + BATTE RY Available space for server Sealed Batteries Electrical distribution Modular UPS COOLING SYSTEM UNIT The system is made of 3 main units: A. External Refrigerant Unit: can work with water as CSG GAS AS REFRIGERANT (ERG) B. Cabinet with cooling system inside, connected to external refrigerant unit through two pipelines (named CSW if water, or CSG if gas). C. Cabinet that can house UPS, batteries and server or only server named SU. CSW SU COOLING SYSTEM UNIT WATER AS REFRIGERANT (ERW) How the Air Condition UPS system works SU The system is a closed system: the cold air comes out (forced by fans) from the front side of the cooling module: then is sucked in UPS and servers by fans. The hot air comes out from the rear part of UPS and servers, and is sucked in the cooling system. A special membrane parts the hot from the cold air. The fans in the cooling unit are redundant and with variable speed, to optimize the energy consumption, and can quickly be replaced without stopping the system. The system is supplied by modular, redundant (N+1) UPS on line, which provides for continuity of power supply (perfect sinusoidal waveform, noise free). The inner sealed batteries provide the energy reserve in case of blackout of the mains. The Air Condition UPS, in a sole cabinet can be equipped with the water or gas refrigerator system, and respectively provided with an external chiller unit or a motor condensing unit. Following the standard data. Technical Data WATER SYSTEM MODEL SHW161 SHW162E1 SHW222E1 SHW323E1 Total cooling capacity kw Number of fans N Air/flow max. (automatic variation of speed) m 3 /h Water flow (at 7-12 C) l/h UPS (N+1) N modules N Power/module kw N max batteries 9Ah/12V N Back up time (N UPS load) min Input voltage V/ph/Hz 400/3+N/50 Output voltage V/ph/Hz 400/3+N/50 Cabinet Physical Data Weight Kg Width mm Height mm Depth mm Server rack unit available U (44,45mm) External chiller unit Input voltage V/ph/Hz 400/3+N/50 Cooling capacity kw GAS SYSTEM MODEL ACG081 ACG081E1 ACG 202E1 Total cooling capacity kw Number of fans N Air/flow max. (automatic variation of speed) m 3 /h Gas refrigerant R410A UPS (N+1) N modules N Power/module kw N max batteries 9Ah/12V N Back up time (N UPS load) min Input voltage V/ph/Hz 400/3+N/50 Output voltage V/ph/Hz 400/3+N/50 Cabinet Physical Data Weight Kg Width mm Height mm Depth mm Server rack unit available U (44,45mm) External motor condensing unit Input voltage V/ph/Hz 400/3+N/50 Cooling capacity kw Air Condition UPS Your Complete Turnkey Server Room Air Condition UPS is a modular system that can be built in different configurations, depending on the needs of the Data Center. Its special feature is the possibility to be be adapted to the Data Center power and dimensions. Moreover it can grow with the Data Center starting from a basic standard configuration optimizing in this way the investment costs to the real needs. Basically two different cabinets are available. Cabinet CSW or CSG. These are the cooling cabinets and they can work with chilled water or refrigerant gas in connection with the external units. They are combined in the modular system to cool the apparatus for server and power UPS. Their number depends on the installed power. Cabinet SU. This type of cabinet can include the server or the battery or the UPS or a combination of them. As from the figure below, it is possible to expand the system combinig the two different cabinets depending on the Data Center requests. The Air Condition UPS smallest configuration includes two cabinets: one cabinet SU for the UPS, battery and server and the other cabinet for cooling type CSW or CSG. Below is a typical configuration with two cabinets CSW, two cabinets SU for server appartus and two cabinets SU for UPS and battery. Air Condition UPS Your Complete Turnkey Server Room OPTIONAL ACCESSORIES PDU POWER DISTRIBUTION UNIT Bar of 20 sockets for servers: it is possible to control (from remote point) each single socket, including on /off switch by program, load current, environment temperature, humidity, water, smoke, open doors. AMBIENT CONTROL Open door Environment temperature and humidity Smoke Water FG FIREGUARD Fire monitoring unit, with 2 smoke probes plus 2 thermo sensitive cables: to switch off the fire there is a special gas cylinder. KVM SWITCHES Monitor and control servers from a single console rack version: switch with 8 or 16 ports, keyboard and touchpad. KEYPAD MODULE The Keypad Module is the processing unit of the Stand-alone electronic locking system. It includes a numerical keypad as well as the data memory and the controller unit for the storage and evaluation of the input. It is possible to connect up to two handles that will be controlled by one master handle. Air Condition UPS Your Complete Turnkey Server Room CONNECTIVITY EBT intelligent solutions for networking allow continuous and assistant monitoring for the Air Condition UPS system. Alarm Remote Monitoring and Control SMS/ Alarm/Voltage Free Contact HTTP SNMP Display Visualisation Operation Remote Maintenance CUSTOMER Air Condition UPS can provide remote information using different ways. The user can get the status through mobile phone, SMS, PDA (personal digital assistant) and internet connections. It is possible to have a display of functional parameters and also an operational control. EBT EURO-Batterietechnik GmbH Philipp-Reis-Str. 7 D Schöneck Tel.: Fax: Mail:
Recommended
View more...
We Need Your Support
Thank you for visiting our website and your interest in our free products and services. We are nonprofit website to share and download documents. To the running of this website, we need your help to support us.

Thanks to everyone for your continued support.

No, Thanks